Sherwood Wisdom 3 Specifications Page 26

  • Download
  • Add to my manuals
  • Print
  • Page
    / 54
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 25
26
Wisdom 3 DC Manual
© 2002 Design, 2011 Doc. No. 12-5274-r01 (8/31/11)
CNS
O2
DECO
N2
SAFE
MINUTES
G
DECO
N2
NITROX
CNS
O2
Pressing Both buttons for < 2 seconds activates the Backlight.
Pressing Both buttons for => 2 seconds reverts to the TIME/WET screen.
The unit reverts to the TIME/WET screen if neither button is pressed in 2 minutes.
SET RESERVE TIME (DTR) ALARM VALUE
Factory set for 5 minutes, the RESERVE TIME ALARM VALUE can also be set from 1 to 30 minutes in in-
crements of 1 minute.
After accepting ON as the setting for RESERVE TIME ALARM ON/OFF, the SET RESERVE TIME
ALARM VALUE screen appears with the set point ashing. Appearing on the screen (Fig. 47) will be -
Alpha graphic RES
Alarm (speaker) icon
• Reserve Time Value, ashing
• Nitrogen and O2 Bar Graphs
• Tank icon
Pressing and holding the side (Select) button scrolls through the Set Points of at a rate of 4 per second.
Pressing and releasing the front (Advance) button accepts the selection and/or advances to SET DECO
ALARM.
Pressing Both buttons for < 2 seconds activates the Backlight.
Pressing Both buttons for => 2 seconds reverts to the TIME/WET screen.
The unit reverts to the TIME/WET screen if neither button is pressed in 2 minutes.
SET DECO ALARM ON/OFF
Factory set ON, the DECO ALARM can also be set OFF. When set OFF, the Alarm will not sound upon en-
try into Decompression Dive Mode.
To access SET DECO ALARM while viewing the SET 2 GO TO screen, press/release the front (Advance)
button 7 times. Appearing on the screen (Fig. 48) will be -
Alpha graphic DECO
Alarm (speaker) icon
• Graphic ON (or OFF), ashing
• Nitrogen Bar Graph
Depressing and releasing the side (Select) button toggles between ON and OFF.
Depressing and releasing the front (Advance) button accepts the selection and advances to SET PO2
ALARM.
Pressing Both buttons for < 2 seconds activates the Backlight.
Pressing Both buttons for => 2 seconds reverts to the TIME/WET screen.
The unit reverts to the TIME/WET screen if neither button is pressed in 2 minutes.
SET PO2 ALARM ON/OFF
Factory set ON, the PO2 ALARM can also be set OFF. When set OFF, the Alarm will not sound upon as the
Level of PO2 increases.
To access SET PO2 ALARM while viewing the SET 2 GO TO screen, press/release the front (Advance) but-
ton 8 times. Appearing on the screen (Fig. 49) will be -
Alpha graphic PO2
Alarm (speaker) icon
• Graphic ON (or OFF), ashing
• O2 Bar Graph
• Graphic Nitrox
Fig. 47 - Set Reserve
Time Alarm
Fig. 48 - Set Deco Alarm
Fig. 49 - Set PO2 Alarm
Page view 25
1 2 ... 21 22 23 24 25 26 27 28 29 30 31 ... 53 54

Comments to this Manuals

No comments