Sherwood Enviro EG40 DV User Manual

Browse online or download User Manual for Tools Sherwood Enviro EG40 DV. Sherwood Enviro EG40 DV User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 39
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
EG40-070
SHERWOOD INDUSTRIES IS AN ENVIRONMENTALLY RESPONSIBLE COMPANY. THIS MANUAL IS PRINTED ON RECYCLED
PAPER.
B Y : S H E R W O O D I N D U S T R I E S L T D
PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE
EG40 DV
OWNERS MANUAL
This appliance may be installed in an after market
permanently located, manufactured (mobile)
home, where not prohibited by local codes.
This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is
not convertible for use with other gases, unless a
certied kit is used.
WHAT TO DO IF YOU SMELL GAS
• Open windows/Extinguish any open ame.
• Do not try to light any appliance.
Do not touch any electrical switch or use any
phone in your building.
Immediately call your gas supplier from a
neighbour’s phone. Follow the gas supplier’s
instructions.
If you cannot reach your gas supplier, call the
re department.
WARNING
If the information in this manual is not followed exactly, a re or explosion may
result causing property damage, personal injury or loss of life. Installation and
service must be performed by a qualied installer, service agency or the gas supplier.
FOR YOUR SAFETY: Do not store or use gasoline or other Flammable vapours and
liquids in the vicinity of this or any other appliance.
Massachusetts installations (Warning): This product must be installed by a licensed
plumber or gas tter when installed within the Commonwealth of Massachusetts. Other
Massachusetts code requirements: Flexible connector must not be longer than 36in., a
shut off valve must be installed; only direct vent sealed combustion products are approved
for bedrooms/bathrooms. A carbon monoxide detector is required in all rooms containing
gas red direct vent appliances.
Page view 0
1 2 3 4 5 6 ... 38 39

Summary of Contents

Page 1 - OWNER’S MANUAL

EG40-070SHERWOOD INDUSTRIES IS AN ENVIRONMENTALLY RESPONSIBLE COMPANY. THIS MANUAL IS PRINTED ON RECYCLED PAPER.B Y : S H E R W O O D I N D U S T

Page 2 - Safety Precautions

Maintenance And ServiceFUEL CONVERSION:Figure 9: Removing valve cap.a) Remove the main burner orice with a  inch deep socket.b) Put a bead of pipe-t

Page 3 - Table of Contents

11Maintenance And Serviceb) Insert a 5/32” or 4 mm Allen wrench into the hexagonal key-way of the screw (see Figure 10), rotate it counter-

Page 4 - Codes And Approvals

Initial InstallationQUALIFIED INSTALLERS ONLYWARNING: Operation of this heater when not connected to a properly installed and maintained venting syste

Page 5 - Specifications

VerticalTerminationStorm CollarFlashingRound SupportBox/Wall ThimbleCeiling FirestopPipelengthPipelengthCathedral CeilingSupport BoxPipelengthRound Su

Page 6 - Operating Instructions

14MOBILE HOME INSTALLATION:• When the unit is installed in a Mobile Home it must be grounded to the steel chassis or connected to a g

Page 7

1 In accordance with the current CSA B149, Natural Gas and Propane Installation Code.2 In accordance with the current ANSI Z223.1 NFPA 54, National Fu

Page 8 - Maintenance and Service

Figure 19: Wire Spacers.Figure 20: Wire Spacer in Place.the structure. 5. Project a level line from the center point of the elbow. Using

Page 9

17Initial InstallationQUALIFIED INSTALLERS ONLYFigure 21: Assembly of Venting Kit.Wall framingHorizontal wallterminationWall thimblefire stopInside fi

Page 10 - Maintenance And Service

Initial InstallationQUALIFIED INSTALLERS ONLY1816. Slide the 90° elbow over the ex pipe. Do not slip the outer sections of pipe together, you will re

Page 11

19Table 4: Vent part numbers (Must state if galvanized or black wanted, PART NUMBERS).Direct Vent GS Direct-Temp Secure Vent Ameri Vent DirectDescrip

Page 12 - Initial Installation

2FOR SAFE INSTALLATION AND OPERATION OF YOUR “ENVIRO” HEATER, PLEASE CAREFULLY READ THE FOLLOWING INFORMATION:• All ENVIRO gas-red appliances must b

Page 13

Figure 23: Vent restrictor ring.Figure 22. Possible Vent Congurations; Vertical and Horizontal Terminations.VENT CONFIGURATIONS:Figures 22 shows the

Page 14

21HORIZONTAL INSTALLATION:1. Set the appliance in the desired location. Check to determine if wall studs or roof rafters are in the way when the vent

Page 15

wall thimble will conceal it (see left image in Figure 26).7. Slide the decorative wall thimble up to the wall surface and attach with th

Page 16

23VERTICAL INSTALLATION:1. Check the instructions for required clearances (air spaces) to combustibles when passing through ceilings, walls, roofs

Page 17

support straps to the roof. Seal the nails holes heads with non-hardening mastic. Trim the excess length of the support straps that extend out beyond

Page 18

25NailsCeiling firestopCeilingSecond floorUse clearances to asdefined by appliance andvent pipe manufacturers.• For multi story installations. A

Page 19

VENTING INTO A CLASS ‘A’ CHIMNEY:This model is also certied and tested to vent into CLASS ‘A’ wood stove chimneys.Place the freestanding direct vent

Page 20

27    

Page 21

Initial InstallationGAS LINE CONNECTION AND TESTING:WARNING: Only persons licensed to work with gas piping may make the necessary gas connections to t

Page 22

29CAUTION: Use only the type of ember material supplied with this appliance. Due to the irregular size of the ember material there m

Page 23

3Table of ContentsSafety Precautions...2Table of Contents...

Page 24

Secondary InstallationCAUTION: NEVER OPERATE THIS APPLIANCE WITH THE GLASS DOOR REMOVED.Place the log set into the rebox. Locate each log by

Page 25

31Trouble ShootingProblem Possible Cause SolutionThe main burner does not ignite when called for.The gas valve may not be on. • Check that the gas

Page 26

Parts ListReference NumberPart Description Part Number1 120 °F (49 °C) Ceramic Temperature Sensor EC-0012 S.I.T. NOVA Valve Convertible 50-14213 Ther

Page 27

33Parts ListReference NumberPart Description Part Number14 Side Panel EG40-086 15 DV Stove Top EG40-087A Firebox Bafe EG40-088Stove Top Bafe DV EG

Page 28

Parts Diagram - ChassisEG 40 Body (Chassis)July 200434

Page 29 - Secondary Installation

35Parts Diagram - Gas Tray & DoorEG40 Gas Tray & Door AssembliesJuly 20042782092324510611162625243

Page 30

WarrantySherwood Industries Ltd. is the manufacturer of the Enviro line of heating products. At Sherwood Industries, our commitment to t

Page 31 - Trouble Shooting

37Warranty4. The stove must be operated and maintained at all times in accordance with the instructions in the Owner’s Manual. If the unit shows signs

Page 32 - Parts List

19. The paint on the Metal Brick Liner may peel. This is due to the extreme conditions applied to the paint during normal usage. It is not a aw and i

Page 33

39Installation Data SheetThe following information must be recorded by the installer for warranty purposes and future reference.NAME OF OWNER:________

Page 34 - Parts Diagram - Chassis

DIRECT VENT: This type is identied by the sufx DV. This appliance draws all of its air for combustion from outside the dwelling, through a spec

Page 35 - July 2004

5SpecificationsDIMENSIONS:25"(635 mm)21"(533 mm)121/2"(318 mm)45/8"(117 mm)291/8"(740 mm)Shipping Weight 256 lbs (116 kg)Figu

Page 36 - Warranty

Operating InstructionsFOR YOUR SAFETY READ COMPLETELY BEFORE OPERATING.LIGHTING INSTRUCTIONS:61. STOP! Read the safety information above on this label

Page 37

ThermopileThermocoupleFigure 4: Gas Valve.Figure 3: Pilot Burning.7• There is a separate venturies for each burner, see Figure 5.• Remove one

Page 38

8Maintenance and ServiceAnnually check to ensure that your Venting system is clear. Periodically check the pilot and burner. Check to see that all the

Page 39 - (dd/mm/yyyy)

9Figure 8: Blower (Fan) Removal.1. Turn the unit off, allow it to cool down completely, and remove the door as shown in the MAINTENA

Comments to this Manuals

No comments